4V300

4v300
Port size: G 1/4’’ i G 3/8"
Type: 3/2-, 5/2- i 5/3-drogowy
CV: 1,40-1,68
Effective Cross Section Area: 25-30 mm2
Model4V310-084V320-084V330C-084V330E-08 4V330P-084V310-10 4V320-104V330C-104V330E-104V330P-10
4A310-084A320-084A330C-084A330E-08 4A330P-084A310-10 4A320-104A330C-104A330E-104A330P-10
Valve Type 5/2 way 5/3 way 5/2 way 5/3 way
Effective Cross Section Area 25 mm2 (CV = 1.40) 18 mm2 (CV = 1.00) 30 mm2 (CV = 1.68) 18 mm2 (CV = 1.00)
Model 3V310-08 3V320-08 3A310-08 3A320-08 3V310-10 3V320 -10 3A310-10 A320-10
Valve Type 3/2 way
Effective Cross Section Area 25 mm2 (CV = 1.40) 30 mm2 (CV = 1.68)
Port Size Supply, Outlet, Exhaust Port = G 1/4" Supply, Outlet = G 3/8" Exhaust Port = G 1/4"
Working Medium 40 Micron Filtered Air
Operation Internal piloted
Working-pressure 0.15-0.8 MPa
Max. Test Pressure 1.2 MPa
Ambient Temperature 5-50 °C
Operating Voltage Tolerance ± 10%
Power Consumption AC: 5.5 VA DC: 4.8 W
Connector Protection F Class, IP 65
Wiring/Connector Cable / Lead Wire or DIN Connector
Switching Frequency 5 Cycles / Sec.
Response Time 0.05 Sec.
Top